How to set CAM traces, when CAM is up and running and when CAM is not working?

Document ID : KB000052377
Last Modified Date : 14/02/2018
Show Technical Document Details

Initially check the status of CAM by running below command,

camstat

  • If CAM is already running, do the following:

    1. Execute this in a DOS prompt:

      camconfig CONFIG "tr_log_files=50"
      camconfig CONFIG "tr_log_size=8192"
      camconfig "trace=all"

    2. Reproduce the issue or wait for it to get reproduced

    3. Collect logs from %CAI_MSQ%\logs

      After the logs are collected run the following command:

      camconfig CONFIG "trace=none" to disable traces

      Otherwise cam performance will get affected.

  • If CAM is not running, do the following:

    1. camclose

    2. cam change disabled

    3. edit cam.cfg with those rules

      *CONFIG
      tr_log_files = 50
      tr_log_size = 8192
      trace=all

    4. cam change auto

    5. cam start

    6. reproduce the issue or wait for it to get reproduced

    7. Collect logs from %CAI_MSQ%\logs

      After the logs are collected edit cam.cfg with this line:

      trace=none

      Otherwise cam performance will get affected