Description:

Here is the steps for reading all records in sys.AUD$ table with Oracle iRecorder again.

Solution:

Oracle iRecorder checks the value of NTIMESTAPM# field in sys.AUD$ table and the iRecorder judges if the records should be read.

For example:

There are 5 records in sys.AUD$ table as follows.

NTIMESTAMP#
11-09-20 02:50:41.375000
11-09-27 04:34:12.265000
11-09-27 04:42:24.843000
11-09-27 04:48:05.671000
11-09-27 04:58:55.843000

  1. Please stop iGateway service.

  2. Please check Oracle.conf file in SharedComponents\iTechnology folder.

    The .conf file has the following line.

    <LastRecordRead NSN="XXX" Table="sys.aud$">MM/DD/YYYY HH24:MI:SS.EF6</LastRecordRead>

  3. Here is the steps for reading all records in sys.AUD$ table with Oracle iRecorder again.

    Please set LastRecordRead the date and time before 11-09-20 02:50:41.375000 as follows.

    LastRecordRead NSN="XXX" Table="sys.aud$">01/01/1980 00:00:00.000000</LastRecordRead>

    That means that the Oracle iRecorder will try and read data from after Jan 1st 1980.

    *The date format in LastRecordRead is MM/DD/YYYY.

  4. Please start iGateway service.

Oracle iRecorder should read all records in sys.AUD$ table.