Problem:

The startup of newly created CICS region gives CA IPC error:

ICPSINIT99E- ERROR DETECTED AT PSS INITIALIZATION
PSS1 RF=8 R0=1 13.49.46 JOB00234 +DFHAP0001 TCICSTI AN ABEND
(CODE 0C1/AKEA) HAS OCCURRED AT OFFSET X'FFFFFFFF' IN MODULE VPEHJN67
 
Environment:
 
z/OS z/VSE
 
Cause:

The message ICPSINIT99E-ERROR DETECTED AT PSS INITIALIZATION PSS1 RF=8 R0=1 is the result of the inability to access ADRPNL and/or ADROUT and is most likely caused by a missing FCT entry.

Resolution:

To verify that there is an FCT entry for ADRPNL and ADROUT, in CICS, issue the command CEMT I FILE(ADR*). This will display all the VLS libraries starting with ADR. Make sure that ADRPNL and ADROUT is listed, along with all of the VLS files. Make sure they are all OPENEd and ENABLEd. The following depicts the result of the command CEMT I FI(ADR)

I  FI(ADR*)                                                   
 STATUS:  RESULTS - OVERTYPE TO  MODIFY               
  Fil(ADRINT  ) Bda Ope Ena Rea                Exc Sha    
         Dsn( IDLT.IPCIDL.R11SUP.ADRTRC           )
  Fil(ADRLIB  ) Bda Ope Ena Rea  Upd Add Bro   Exc Sha  
         Dsn(  IDLT.IPCIDL.R11SUP.ADRLIB          )
  Fil(ADROUT  ) Bda Ope Ena Rea  Upd Add Bro   Exc Sha
         Dsn( IDLT.IPCIDL.R11SUP.ADROUT             )
  Fil(ADRPNL  ) Bda Ope Ena Rea  Upd Add Bro   Exc Sha
         Dsn(  IDLT.IPCIDL.R11SUP.ADRPNL            )