How to add more CCI terminals to CA 7 Workload Automation.

Document ID : KB000025556
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

This Knowledge Document describes how to define additional CCI terminals for CA 7 Edition. Also, please see the Systems Programmer Guide, chapter 5 for a description of the Initialization File statements and keywords, and the Interface Reference Guide, chapter 3 topic - Interface With CAICCI.

Solution:

If you need additional CCI terminals in CA 7 Edition, you must update Initialization File (pointed to by the UCC7IN DD statement in the CA 7 online procedure). You will need to add a GROUP, LINE, TERM, and STATIONS statement for each added terminal as such:

GROUP,NAME=CCIGRP2,DEVICE=CCI,LNAME=CCILN2
LINE,NAME=CCILN2,BUFSIZE=3120,TNAME=CCIT2
TERM,NAME=CCIT2,DEVICE=CCI,NLINE=60,LINLEN=137,CONS=ALTRN
*
GROUP,NAME=CCIGRP3,DEVICE=CCI,LNAME=CCILN3
LINE,NAME=CCILN3,BUFSIZE=3120,TNAME=CCIT3
TERM,NAME=CCIT3,DEVICE=CCI,NLINE=60,LINLEN=137,CONS=ALTRN
.......
STATIONS,TRMID=CCIT2,STANIDS=(CCI2)
STATIONS,TRMID=CCIT3,STANIDS=(CCI3)

These statements are positional. You will add the GROUP, LINE and TERM statements after the existing ones for CCI terminals and add the STATIONS statements after the SECURITY statement (grouped with the other STATIONS statements). Note that STANIDS values must be unique.

After this you will need to do a specified ERST type start up of CA 7 Edition follows:

S CA7ONL,TYPE=ERST