How does one use ALTID=N in a CA Endevor processor?

Document ID : KB000012605
Last Modified Date : 14/02/2018
Show Technical Document Details
Question:

The ALTID is being used for allocate/delete of permanent files in a processor using iefbr14 and IDCAMS delete; is there any way to turn the ALTID off for the steps within the processor?

Answer:

ALTID=NO should be used on the processor EXEC PGM= step for those programs being executed that no swap is to occur.

Example:

//STEP1     EXEC PGM=IDCAMS,ALTID=NO