Hitachi Probe Resource Test fails

Document ID : KB000094118
Last Modified Date : 05/07/2018
Show Technical Document Details
Issue:
  • After deploying the Hitachi Probe a resource was added and then the Test button clicked to populate the Organizations field.
  • The Test fails and there is a popup error window with:
Unexpected application error occured. 
InvalidArgument=Value of '0' is not valid for 'index'.
Parameter name: index
Resolution:
  • Ask the Storage Admin for the correct Namespace to use. 
  • The default is root/smis/current but that is configurable and if changed, Namespace field must match how the Storage Admin has it set, for the Test to succeed. 
  • Please also make sure the IP to hostname mapping in your environment is correct, otherwise the error may still occur.
  • Try using the IP address instead of the hostname to verify.
File Attachments:
hitachi-test.jpg