GIM30206E for SMPE APPLY CHECK for RO64305 and RO66636.

Document ID : KB000014452
Last Modified Date : 14/02/2018
Show Technical Document Details
Introduction:

How to resolve a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636.

 

Question:

Getting a GIM30206E when doing an APPLY CHECK for RO64305 and RO66636:

 

APPLY CHECK          SELECT   (                    RO64305                    RO66636                   )          RETRY(YES)          GROUPEXTEND                 . GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO64305. HOLD REASON IDS WERE NOT RESOLVED. GIM35965I    SYSTEM HOLD ACTION ORIGINATED BY SYSMOD RO64305 WAS NOT RESOLVED. GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD RO66636. HOLD REASON IDS WERE NOT RESOLVED. GIM35965I    SYSTEM HOLD DYNACT ORIGINATED BY SYSMOD RO66636 WAS NOT RESOLVED. GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND. GIM20501I    APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12. GIM20502I    SMP/E PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 12. SMP/E IS AT LEVEL 35.50.1PAGE 0001  - NOW SET TO TARGET ZONE TZONE2   DATE 05/18/17  TIME 16:52:44  SMP/E 35.50   SMPRPT   OUTPUT   APPLY CHECK          SELECT   (                    RO64305                    RO66636                   )          RETRY(YES)          GROUPEXTEND
Answer:

BYPASS(HOLDSYSTEM,HOLDERROR,HOLDUSER)

can be added to the APPLYCHECK control statement to get you around the error.