Getting DB01909E and DB01911E errors on the MUF SYSIN card at Multi-User startup

Document ID : KB000019315
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

MUF region fails to start because of the following error messages:


DB01900I - MUF  mufname,99,YES        
DB01909E -             * - ASTERISK POINTS NEAR ERROR 
DB01911E - PARAMETER HAS INVALID VALUE   

The following error is also returned:


  DB00216E - ERROR IN SYSIN/SYSIPT DATA.

Solution:

These messages are returned when the "mufname" specified in the above MUF card is not an asterisk (*) and doesn't match any of the MUF logical names specified in TARGET_MUF_LIST parameter of the DBSYSID macro (DBSIDPR module).

Product Document Change (PDC) RI55039 for CA Datacom version 12.0 and RI55040 for CA Datacom version 14.0 contain the changes to the CA Datacom manuals about this MUF option.

For MUF regions running in a Shadow MUF environment , see also Technical Document TEC505004