Getting CAS9182A message for PROD(IE)

Document ID : KB000033217
Last Modified Date : 14/02/2018
Show Technical Document Details

Symptoms:

You are noticing CAS9182A messages in the system log every 15 minutes warning that the LMP key for PROD(IE) is going to expire.

CAS9182A WARNING: LMP key Prod (IE) expires in 029 days.

Product code 'IE' is the code for Insight for DB2 which you do not have installed.

 

Cause:

Being that you are not running Insight for DB2 and therefore do not have an LMP key for this product, the reason can be tied to your execution of CA SYSVIEW and its configuration options.

 

Resolution:

  1. Review the CA SYSVIEW started task JESMSGLG. Here you should see the configuration options in affect. Look for the option Component-DB2 and whether the value is set to Yes or No. Because you are getting the LMP message the expectation is that the value is set to Yes. Here is a sample of the message you should find in the SYSVIEW JESMSGLG.
    GSVX998I (MAIN) GSVX745I*GSVXGSVX |Option-TCPIP                     No
    GSVX998I (MAIN) GSVX745I*GSVXGSVX |Option-WebSphereMQ               No
    GSVX998I (MAIN) GSVX745I*GSVXGSVX |Component-DB2                    Yes   <---
    GSVX998I (MAIN) GSVX745I*GSVXGSVX |Component-Health-Check           Yes
    GSVX998I (MAIN) GSVX745I*GSVXGSVX |Component-MIM                    Yes
  2. Locate and edit the CA SYSVIEW System Configuration Options member (eg. GSVXGSVX) and modify the value for Component-DB2 to No.
  3. Recycle the CA SYSVIEW address space.