Getting a C1A0010E Allocation error adding a Processor

Document ID : KB000122926
Last Modified Date : 31/12/2018
Show Technical Document Details
Issue:
I'm am updating a COBOL 6 processor and getting the following error:

C1A0010E  ALLOCATION ERROR RC=1708-0002, DDNAME=SYSLIB                         
C1A0011E  IKJ56228I DATA SET SYS5.NDVR.CSIQOPTN NOT IN CATALOG OR CATALOG CAN NOT BE ACCESSED 



I was able to generate the processor earlier without any problems. What is wrong?
Environment:
All supported version of CA Endevor SCM
Cause:
When a Processor is added to Endevor, it is generated using the internal GPPROCSS processor which uses the CSIQOPTN library specified in the C1DEFLTS table. 
The C1A0011E message indicates that the CSIQOPTN library specified in the C1DEFLTS is not found.  
Resolution:
Verify the CSIQOPTN library specified in the C1DEFLTS keyword MACDSN is pointing to the correct CSIQOPTN library.