GET_ATT: U00020792 Runtime error in object 'JOBS.WEBSERVICE.REST.NEW.1(1)', line '00001': Value of paramter '1' too long. Allowed length is '30'.

Document ID : KB000087373
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
U00020792 Runtime error in object 'JOBS.RA.1(1)', line '00001': Value of paramter '1' too long. Allowed length is '30'.

Using GET_ATT or PUT_ATT fails when the attribute name of a Rapid Automation job is more than 30 characters or 32 bytes.
 
Environment:
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: PUT_ATT / GET_ATT not working for RA jobs with attribute names longer than 32 characters.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 12.0.0 - Available
Automation Engine 11.2.3 - Available
Automation Engine 11.1.4 - Available
Additional Information:
Workaround :
N/A