Issue:
Error Message :
03.02.2016 09:04:55 - U00010009 Runtime Error in 'JOBS.UNIX.TEST' (RunID 'XXX'): Interpreter Definition for Interpreter 'INTERPRETER' in Variable 'UC_EXT_INTERPRETERS_UNIX' not found.

Jobs using an external Interpreter fail with:

03.02.2016 09:04:55 - U00010009 Runtime Error in 'JOBS.UNIX.TEST' (RunID 'XXX'): Interpreter Definition for Interpreter 'INTERPRETER' in Variable 'UC_EXT_INTERPRETERS_UNIX' not found.
Cause:
Cause type:
Defect
Root Cause: Variable Scope of UC_EXT_INTERPRETERS_XXX is set to host instead of freely selected.
Resolution:
Update to the Release Version below or a later one.

Fix Status: Released

Fix Version(s):
Automation Engine 11.1.3 - Available
Additional Information:
Workaround :
Manually set the scope of UC_EXT_INTERPRETERS_XXX to freely selected.