Export of data from the Workstation is impacted by "Data limited to 100 matching metrics" in the data viewer

Document ID : KB000005140
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

A Workstation data viewer for a metric grouping shows message "Data limited to 100 matching metrics". This is also impacting the export of all the required data i.e. data is limited to only 100 metrics.

Cause:

The default workstation data viewer limit is 100 metrics and is designed to prevent a workstation performance problem.

It can be increased by adding hidden property introscope.enterprisemanager.workstation.viewerMetricLimit to the IntroscopeEnterpriseManager.properties file. 

However care should be taken to avoid any negative Workstation performance impact. 

Resolution:

The safer option is to use the Command Line Workstation (CLW) to export all the required agent metric data

APM Command-Line Workstation > CLW Command Reference > Extract Persistent Data from SmartStor (Within a Time Range)

Additional Information:

To run CLW you just need a local copy of the CLWorkstation.jar file and you can run it to connect to a remote Enterprise Manager server

APM Command-Line Workstation