Issue:

We have installed a 11.3 System Agent successful on a Windows system.
Autoping works fine. User and password are defined within autosys_secure. 

Test job is submitted and ends with exitcode -655.

 

[03/08/2017 10:06:53] CAUAJM_I_40245 EVENT: FORCE_STARTJOB JOB: testjob 

[03/08/2017 10:06:53] CAUAJM_I_40245 EVENT: CHANGE_STATUS STATUS: STARTING JOB: testjob MACHINE: win_agent 

[03/08/2017 10:06:54] CAUAJM_I_40245 EVENT: ALARM ALARM: STARTJOBFAIL JOB: testjob MACHINE: win_agent

[03/08/2017 10:06:54] <Owner attribute error. User does not exist in the system> 

[03/08/2017 10:07:04] CAUAJM_I_40245 EVENT: CHANGE_STATUS STATUS: FAILURE JOB: testjob MACHINE: win_agent EXITCODE: -655

 

Environment:
11.3 SP7 System Agent on Windows
Cause:

Machine definition contains wrong node_name.

Resolution:

Adapt machine definition with correct node_name.