Error Running Cas9

Document ID : KB000049577
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

Installed CCS v14.0 for first time on new system. Executing CAS9 for the first time to install a product LMP key. The CAS9 job abends immediately with the following:

SYSTEM COMPLETION CODE=0C4 REASON CODE=00000004   
TIME=09.58.15 SEQ=00080 CPU=0000 ASID=0036   
PSW AT TIME OF ERROR 070C2000 00C6B0FE ILC 4 INTC 04   
ACTIVE LOAD MODULE ADDRESS=00C6B000 OFFSET=000000FE   
NAME=CAS9GLVL

Solution:

Verify whether CAW0LINK was mistakingly placed in LPALSTxx. Only CAW0LPA should be added to LPALSTxx. Any improperly defined library to LPALST must be removed and an IPL be performed.

Beginning with the installation of CA Common Services v14.0 the following configuration requirements must be met...

  • yourHLQ.CAW0LOAD and CAW0LINK must be apf-authorized

  • yourHLQ.CAW0LINK must be placed in the system LINKLIST. (optionally CAW0LOAD can be linklisted)

  • yourHLQ.CAW0LPA must be added to SYS1.PARMLIB member LPALSTxx