Error accessing the OPSVIEW panel 4.5.1 - AOF Control panel to work with rulesets and rules.

Document ID : KB000005946
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Occasionally the following error messages may be issued when the user tries to access the OPSVIEW panel 4.5.1 - AOF Control:

RUNNING OPAOCM LINE 0: COMPILER WORK SPACE OVERFLOW (1976 1024)         

ERROR 5 RUNNING OPAOCM, LINE 0: MACHINE RESOURCES EXHAUSTED, CODE=3     

ERROR 45 RUNNING OP450000, LINE 60: NO DATA SPECIFIED ON FUNCTION RETURN

If the TSO user sets PROFILE MSGID the following message prefixes may appear:

 OPS0998E RUNNING OPAOCM LINE 0: COMPILER WORK SPACE OVERFLOW (1976 1024)       

 OPS1005I ERROR 5 RUNNING OPAOCM, LINE 0: MACHINE RESOURCES EXHAUSTED, CODE=3   

 OPS1045I ERROR 45 RUNNING OP450000, LINE 60: NO DATA SPECIFIED ON FUNCTION RETURN                                                                              

Environment:
CA OPS/MVS, z/OS, TSO, ISPF
Cause:

The errors occur because the AOF REXX WORKSPACE set for this user is too small for the number of rulesets and rules defined on this system.

Resolution:

Go to OPSVIEW panel 0.1 (0 Parms; 1  General Settings) and increase the value of the parameter "AOF REXX WorkSpace":

 

General Settings ---- XE65 --- O P S V I E W ----------------------------

                                                                         

 OPSCMD Max Lines     ===> 1000  ( 1 to 5000 )                           

 OPSCMD Wait Time     ===>       ( blank for default, or 1 to 60 )       

 OPSCMD Echo          ===> N     ( Y or N )                              

 OPSCMD Subsystem     ===> OPSS                                          

 Action Verification  ===> Y     ( Y or N )                              

 AOF Test Action Ver  ===> Y     ( Y or N )                              

 Max Test Globals     ===>        ( blank for default, or 1 to 999999 )  

 Max Test Temp GLVs   ===>        ( blank for default, or 1 to 99999 )   

 AOF Alloc Subsys     ===>       ( blank for default, or subsystem name )

 AOF REXX WorkSpace   ===> 1572864    ( blank for default, or            

                                      40960 to 2000000000 )              

 SSM Monitor Display  ===> E     ( B/V/E )                               

 SSM Verify mode      ===> N     ( A/M/N )                               

 Clear OPSLOG profile ===> Y     ( Y or N )                              

                                                                         

                                                                         

                                                                         

Enter CANCEL to abort.                                                   

Enter END to confirm settings.              

You may have to increase the value in small amounts several times until the problem is solved. 

                            