E190102 GPC Server Internal exception encountered E180011 Login failed using Artifact UserSession

Document ID : KB000100082
Last Modified Date : 27/07/2018
Show Technical Document Details
Issue:
wcc -> configuration tab.
Attempts to validate the server failed 
Error: E190102 GPC_Server - Internal exception encountered: E180011 Login failed using: Artifact=UserSession;Version-1.0;9942f090fb0d5c729fa66b429668abd1-5b060102-6c3337d0-cc.
Environment:
Product - Workload Automation AE 11.3.x
Product - Workload Control Center 11.4.x
Platform - Windows, UNIX, Linux
Database - Oracle, SQL, Sybase, Derby
Resolution:
WCC Server validation failures can happen if the EEM settings within AE are not consistent with those listed in WCC's AE server definition.
Example: in autosys_secure AE lists that it is in NATIVE security mode while in WCC's server definition it shows AE as being EEM Enabled.
Errors may also occur if AE is pointing to a different EEM than WCC, where the two EEM's are not configured in a trusted / HA mode.

Review autosys_secure's EEM settings and WCC's EEM settings.
See: /opt/CA/WorkloadCC/data/config/application/config/resources/connection.properties
 eem.host=