Dynamic Group filter in USM is not working and count come down zero

Document ID : KB000107911
Last Modified Date : 02/08/2018
Show Technical Document Details
Issue:
Created dynamic group in USM with filters and after applying filters we get all the servers added to that group. But after refreshing the USM page or relogin to UMP, dynamic group servers count automatically comes to zero.
Environment:
UIM: 8.4.7
 
Resolution:
1. Deactivate trellis and udm_manager probes on Primary hub robot and Deactivate the wasp probe on UMP robot.
2. Go to UMP robot server and delete the wasp-engine folder present in ~\Nimsoft\probes\service\wasp\work directory.
3. Download the file das-8.4.7.0.zip 
4. Drag and drop das package to Primary hub robot.
5. Once it is deployed, Activate trellis and udm_manager probes on Primary hub robot and Activate the wasp probe on UMP robot.
6. Open the browser and clear the browser cache.
7. Login to UMP and then check the scenario again.
File Attachments: