Device Disappears When Added to the net_connect Probe.

Document ID : KB000006381
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Devices are added to the net_connect probe but quickly disappear from the list after saving. 

Environment:
UIM Version: 8.47 +net_connect probe v 3.31 +
Cause:

Profile names are given the same name as a site name. This causes a conflict in the organization of the profiles leading them to be removed. 

Resolution:

Change either the site name or the profile name so they do not match each other should allow the profile to remain visible. 

Additional Information:

More information can be found in the probe documentation. 

https://docops.ca.com/ca-unified-infrastructure-management-probes/ga/en/alphabetical-probe-articles/net_connect-network-connectivity-monitoring/net_connect-im-configuration