Issue:
When editting a map in MAPC, error message DC365434 is possible if the access is via a UCFTSO connection.
Environment:
CA IDMS, all supported releases.
Cause:
In the SYSGEN OLM statement, FIELD START CHARACTER is set to x'1E'.
This is not possible under UCFTSO because it will be interpreted as a command delimiter.
Resolution:
In the SYSGEN OLM statement, change FIELD START CHARACTER to x'7C'.
This change will not impact existing maps.
The FIELD START CHARACTER is only relevant during map editting.
Additional Information:
OLM Statement -- Define OLM Characteristics