Question:

My MUF is running fine. 
But my Datacom DBUTLTY job fails with error:
 
DB13001E - UNEXPECTED RETURN CODE 44 (76) SECURITY ENVIRONMENT ERROR ?



 

 

 

Environment:
z/OS 
CA Datacom 14.0 or 15.x
 
Answer:

Although this can be a security issue most often this problem is due to the Datacom PC CALL module(s).

For CA Datacom/DB or CA Datacom/AD Version 15.x,
  PC CALL module  DBPCCPR has not been successfully loaded via CAIRIM. 

For CA Datacom/DB or CA Datacom/AD Version 14.0,
  
PC CALL modules DBPCCPR and DBPCSPR have not been successfully loaded via CAIRIM. 
 
Run DBUTLTY REPORT MEMORY=MVS and check if you see the PC CALL modules .

DBPCSPR needs to be loaded when using DBSIDPR with  CONNECT_ALLOW_PRIORITY=(LOCAL,XCF) .
So if XCF access is needed then load both PC CALL modules  for version 14.0.
If no XCF access is needed then redo the assemble/link-edit for DBSIDPR  with  CONNECT_ALLOW_PRIORITY=(LOCAL)

 

Additional Information:

When you do not load the PC CALL modules via CAIRIM then the first  MUF startup loads DBPCCPR .
Only DBPCCPR.