Copy of a sequential dataview record to PROD gives error DDOL001120C and DSF internal error SRV050

Document ID : KB000073057
Last Modified Date : 11/03/2018
Show Technical Document Details
Issue:
I added some fields to a record for a modeled sequential file Dataview but when I try to copy the RECORD from T001 to PROD I get error message:
​
DDOL001120C - ERPP - DSF INTERNAL ERROR, RC=SRV050

And the following:
------------------------------------------------------------------------
DSF Error Panel E01D 

DSF called by program DDMCFPR at location 108E Miscellaneous Info 
Command: STRCOPY Return Code: 050 Error Module: SRV ------------------- 
Database Id..: 0002 
Resolution:
The SRVnnn errors occur when an attempt is made to copy the FILE structure at the RECORD level.  For  a modeled sequential file dataview, you have to do the copy at the FILE level not at the RECORD level.

After you make all the changes to the record, the procedure to implement the changes are as follows:
  1. Copy the FILE structure to PROD
  2. Copy the DATAVIEW to PROD
  3. Enable the FILE structure
  4. CATALOG the DATAVIEW
Additional Information: