Component Time slower than log entry Time for MTP TIMs.

Document ID : KB000007905
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

  The TIM log shows that the log entry timestamp was just over a minute ahead of the component timestamp on the same line. This also caused immediate missing response defects when the component timeout was one minute. 

Environment:
Any supported APM/MTP Release
Cause:

Determined that Napatech clock was 1 minute+ behind system time.

Resolution:

 Resynch the Napatech clock with the system time.  Napatech - Qualifying, Fine-Tuning and Troubleshooting Time Synchronization