Clarity PMO Version 2.0 Upgrade Error XOG-3052: Query record has not been inserted

Document ID : KB000052477
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

Installing PMO Version 2.0 Upgrade is generating the following error message:

<Description> XOG-3052: Query records has not been inserted com.niku.union.persistence.nsql.NSQLSyntaxException: NSQL Syntax exception:NSQL_SYNTAX_ERROR_UNKNOWN_CONSTRUCT,Info:@SELECT:DIMP_PROP:USER_DEF:datenotime:TRX:A.Task_Start:Task_Start@&#xd;
at com.niku.union.persistence.nsql.NSQLStatementSet.checkRemaingNSQLConstructs(NSQLStatementSet.java:590)&#xd;

Solution:

Check to ensure that the PMO Version 2.0 is being installed in a Clarity 8.1.5+ or Clarity 12.0.5+ environment. PMO 2.0 is only compatible with the minimum releases of Clarity 8.1.5+ or Clarity 12.0.5+.