CCC is not showing memory information for physical servers

Document ID : KB000004646
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

When importing data into Datamanager using a UIM datasource for physical servers which pulls data from UIM cdm probe ,  CCC is not showing memory information for these servers

Environment:
Capacity data manager with Capacity Command Center
Cause:

The CDM probe in UIM needs to provide the memory information in MB otherwise the Data manager data source can not calculate the needed

metrics..

 

 

Resolution:

There are two options in the CDM probe provide memory usage in % or MB . 

The Data manager data source is calculating this from the memory metric in MB. which needs to be enabled in the UIM cdm probe .

Enable The following QOS message in the cdm configuration tool

Memory Usage

Memory in %

Physical Memory usage 

Physical Memory in %