CAS9025A - NO SECURITY SYSTEM AVAILABLE When Installing CA Top Secret 14.0 With CA Mainframe Software Manager (CA MSM).

Document ID : KB000052677
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

After installing CA Top Secret 14.0 using CA MSM (CA Mainframe Software Manager), the following error is received when IPLing:

 CAS9115I - INPUT:  PRODUCT(CAIRIM) VERSION(S910) INIT(S910INIT)
 IEF196I CAS9115I - INPUT:  PRODUCT(CAIRIM) VERSION(S910) INIT(S910INIT
 )
*CAS9025A - NO SECURITY SYSTEM AVAILABLE
 IEF196I CAS9025A - NO SECURITY SYSTEM AVAILABLE
 R 55,TSS
*55 CAS9026A - REPLY WITH SECURITY SYSTEM, "ACF2", "TSS", "RACF" OR "N"
  TO CANCEL
 IEF196I CAS9026A - REPLY WITH SECURITY SYSTEM, "ACF2", "TSS", "RACF"
 OR
 IEF196I "N" TO CANCEL
 IEE600I REPLY TO 55 IS;TSS
 CAS9023E - CAISSF INITIALIZATION ERROR - ROUTINES MISSING OR ALREADY
 PRESENT
 IEF196I CAS9023E - CAISSF INITIALIZATION ERROR - ROUTINES MISSING OR
 IEF196I ALREADY PRESENT
 CAS9140E - INIT ERROR: CAIRIM               VER S910, INIT ROUTINE
 RC=0008
 IEF196I CAS9140E - INIT ERROR: CAIRIM               VER S910, INIT
 IEF196I ROUTINE RC=0008
 CAS9115I - INPUT:  PRODUCT(CA-ADAPTER-CMP) VERSION(YD53) INIT(YD53INIT
 )

Solution:

These errors are most likely the result of installing CA Top Secret 14.0 selecting PDS/E datasets for the CAILPA library.

LPA type libraries cannot be PDSE libraries. This is not a CA Top Secret restriction, but a z/OS one.

CA Top Secret needs to be reinstalled with CA MSM using PDS libraries.