Cannot validate instance in WCC. E190099 DVL - Connection exception encountered. CAUAJM_E_10032 Unable to create server object for host

Document ID : KB000012585
Last Modified Date : 14/02/2018
Show Technical Document Details
Question:

We are unable to validate our new AE instance within WCC.  

E190099 DVL - Connection exception encountered. CAUAJM_E_10032 Unable to create server object for host [us-wcc1]..

E190099 DVL (monitoring id validation) - Connection exception encountered. CAUAJM_E_10032 Unable to create server object for host [us-wcc1]..

 

Environment:
Workload Automation AE 11.3.6.xWorkload Control Center 11.4.xPlatform - ANY
Answer:

Confirm that the AutoServer port # is consistently defined and configured on both the AE and WCC hosts.

Check $AUTOUSER/config.$AUTOSERV to confirm the port number.

And run the following to display its configuration settings:

$CSAM_SOCKADAPTER/bin/csmconfigedit port=<port> display

To make adjustements:

$CSAM_SOCKADAPTER/bin/csmconfigedit port=<port> enablessl=<value> enablepmux=<value>

 

Additionally 

Confirm that the hosts can resolve and reach one another using both their short and fully qualified host names.

Check with your network and firewall teams if adjustments such as updating /etc/hosts files or opening ports in the firewall are needed.