Cannot Trace Server-to-Server Modules in TSO Test Facility

Document ID : KB000007291
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Get the following linkedit error when installing with trace a module with pstep use statement(s):

IEW2456E 9207 SYMBOL TIRPUSE UNRESOLVED MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.

 

 

 

 

 

 

Environment:
z/OS
Cause:

When installing for trace, CA Gen link process imports TIRARUNT which does not contain the module TIRPUSE (by design).  This module is needed when the pstep-use statement is contained in a module.  When installing without trace, Gen imports TIRARUNC (CICS) or TIRARUNI (IMS) and they both contain TIRPUSE.

Resolution:

By design, cannot trace server-to-server modules using the TSO Test Facility.  Use DTF (Diagram Trace Facility) in CICS to trace.