Symptoms: 

When attempting to configure probes on a secondary (remote) hub connected via a hub tunnel, a MONS-002 error occurs similar to the following:

MONS-002 error dialogue

Environment:  

On all hubs:

UIM version: 8.4
ppm: 3.3
baseline_engine: 2.71
hub: 7.8
robot:  7.8
mpse: 1.72

Cause: 

The mpse probe should only be installed on the primary hub.  Having this probe installed and activated on all hubs in the UIM environment was causing the MONS-002 errors when attempting to configure probes on the remote hubs.

Resolution/Workaround:

Delete the mpse probe from all hubs except for the primary hub.