CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00

Document ID : KB000016749
Last Modified Date : 14/02/2018
Show Technical Document Details
Question:

CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00 and CADT008D Mount message and the tape job will hang.

What could be the reason and how to avoid it ?

Answer:

CADT087E UNABLE TO CONTACT SERVER RTC=2F IUCVCODE=00 
RTF=2F means REQUEST EXPIRED (time out) if operator does not reply to CADT008D between 40 Min.

(40 Minutes is the Default). 

 

CADT008D need to be answered in this time to avoid CADT0087E with RTF=2F

Additional Information:

other RTC Codes and action to solve:

2F REQUEST HAS EXPIRED (TIMED OUT)                                           

1D REQUEST UNSUCCESSFUL   (out of IUCV path)                                                     

1E PATH HAS BEEN SEVERED                                                     

IUCV PATH's empty or IUCV Connection to DYNAMCMS Server was broken (perhaps of IPL VSE).

recomendation: increase OPTION MAXCONN in the CP DIRECTORY for VSE       

restart DYNAMCMS to recreate the IUCV interface.