Problem:

After PEND command was entered while shutting down a VSE machine, the following error message was received: CAAU201E CA-AUDIT RUNTIME SYSTEM ERROR 0702

 

Cause:

This message occurs when Audit is running as a subtask of POWER.

 

Resolution:

Audit should be stopped by running the following job just before PEND:
// EXEC CACCDBU0,SIZE=100K
SHUTDOWN AUDIT IMMEDIATE(YES)
/*

 

Additional Information:

An abbreviated format of the command can be used as follows:

SHUT AUDIT IMM(YES)