CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT*

Document ID : KB000124459
Last Modified Date : 16/01/2019
Show Technical Document Details
Issue:
We received SVC Dumps for the CA Detector and Detector Collection stopped and was restarted.
SS50 01/08/2019 15:28:33 DB2PPTX CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT* 108.T202833.S00013 SS30 01/08/2019  DB2PPTX CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT* SYSP.BSYSSS30.N190108.T201914.S00018 SS70 01/08/2019 :15 DB2PPTX CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT* SYSP.BSYSSS70.N190108.T201414.S00003 SS90 01/08/2019 :05 DB2PPTX CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT* SYSP.BSYSSS90.N190108.T200204.S00002 
Environment:
z/os DB2
Cause:
incorrectly set dispatching priority for the xmanager address space
Resolution:
Ensure the dispatching priority for the xmanagers are set correctly as per the Detector documentation