CA OPS/MVS Event Management and Automation - SSMGA: Current and desired states were not updated correctly for moveable resources.

Document ID : KB000004008
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

CA OPS/MVS Event Management and Automation - SSMGA: Current and desired states were not updated correctly for moveable resources.

Environment:
z/OSCA OPS/MVS - SSMGA
Cause:

Problem with optional columns.

 

Resolution:
  1. Set the SSMDEBUG parm to YES.
  2. Look for the following messages in the OPSLOG:

    OPS1000I ? LST update count is 1 records. RC=00000
    OPS1000I ? SSM local STCTBL.$RKIRSS1 ACTIVE MVSG.OPSS MVSG.OPSS MVSG.OPSS INACTIVE RC=87406

    The RC=87406 indicates a problem with the optional columns in you resource table. SSMGA builds an optional column list based the ZSCOLFLG column in the SSMGA_#G#_STATUS and SSMGA_#L#_STATUS tables. Check the tables for these Values. If you have a SCHEDMODE column you should see a value of YYYYYYYY for all rows that represent a resource. If you do not have a SCHEDMODE Column the ZSCOLFLG column should be set to YYYYYNYYY.

  3. To re-sync these columns you should recycle SSM on all systems by setting the STATEMAN parm To INACTIVE then back to ACTIVE.