CA Endevor ADD action failing with a C1U0919E error

Document ID : KB000100543
Last Modified Date : 12/07/2018
Show Technical Document Details
Issue:
Having an issue with a abending retrieve job  --
C1G0202I  ACTION #1 / STMT #2                                                   
C1G0203I     ADD      ELEMENT PRODADD                                           
C1G0205I        FROM DSNAME:  @H8879.T.MO.JCLLIB                                
C1G0204I        TO   ENVIRONMENT: ISPCPROD SYSTEM: RFMNDVR  SUBSYSTEM: MO       TYPE: JCLLIB   STAGE ID: 1
C1G0232I        OPTIONS:  CCID: 0RFMN                                           
C1G0232I                  COMMENT: RETREIVE    xxxxxxxxby xxxxxxx               
C1G0265I  PROCESSOR GROUP *NOPROC* FOR THIS ELEMENT WAS OBTAINED FROM PRIMARY ELEMENT TYPE 
C1U0919E  CCID 0RFMN        IS DEFINED, BUT YOU CANNOT USE IT FOR THAT ELEMENT  
C1G0277I  ADD PROCESSING TERMINATED BECAUSE OF THE PREVIOUS ERROR
C1G0200I  ELEMENT ACTION REQUEST PROCESSING COMPLETED, HIGHEST ENDEVOR RC WAS 0012
END OF EXECUTION LOG - HIGHEST ENDEVOR RC = 0012                                 
              

 
What is the problem?  and how do we fix it?
Cause:
The CCID specified in the ADD action is not eligible for use with the element.

The CCID Validation file used in the above ADD SCL example contained the following entries for CCID 0RFMN: 

1 3            16       25      34 36       45       54       63
* CCID         USERID   ENVIRON  # SYSTEM   SUBSYS   TYPE     ELEMENT
  0RFMN        *                   RFMNDVR  MO*      TSASLIB       
  0RFMN        *                   RFMNDVR  MO*      TJCLLIB       
  0RFMN        *                   RFMNDVR  MO*      SASLIB        
  0RFMN        *                   RFMNDVR  MO*      JCLLIB   R*   


For System RFMNDVR ; Subsystem MO ; Type JCLLIB,  Elements must start with R.
The Element being added starts with P, so the CCID 0RFMN is not allowed. 
Resolution:
To determine what CCIDs are eligible, you need to check the CCID Validation Data Set.

1.  log on to Endevor and on the Environment Selection List panel, select one of the Environments
2.  Go to    1  DISPLAY  >>  3  SITE   and go to the second Site Information from C1DEFLTS panel
3.  In the Control Data Set Names section in the middle of the panel, look for the  CCID Validation Data Set  line and get the name of the CCID Validation data set 
4. Review the definitions in the CCID Validation data set and use the appropriate CCID as defined in the data set, update an existing CCID definition or add a new CCID definition if needed. 
 
Additional Information:
See 'Using the CCID Definition Data Set' section in the Endevor DocOps for information on coding CCID defintions.