CA-1 MACLIB (CTAPMAC) Inquiry

Document ID : KB000112162
Last Modified Date : 27/08/2018
Show Technical Document Details
Issue:
When trying to install the CTRX001 exit from BMC so that Control-R will interface with CA 1 it is failing to assemble.  Seems to be a problem with the TMMLINK macro that they are using.  This code is distributed by BMC.
Resolution:
The sample exit supplied by BMC in CONTROL-R to interface with CA 1 uses the CA 1 TMMLINK macro, but did not include the SSI= parameter.  The value specified for the SSI keyword is limited to 7 characters.

You should also include an update to the CTAPOPTN member TMOKEYxx to assign a BATCHID to the CTRX001 exit.  Here is an example of what you can code in the TMOKEYxx member
BATCH_ID_61=CTRX001
  
To pick up the change to TMOKEYxx, simply run TMSINIT.