Description

C1LB006E message is inconclusive, this FAQ outlines some possible reasons for the message.

Solution

The 'C1LB006E library open failed' message does not supply information about the specific cause.

To diagnose the problem, investigate accompanying messages, for example a IEC161I, and the reported RC and SFI in that IBM message.

If the ELIB file is under L-Serv control, check the L-Serv log for LDM error messages.

Possible causes of this error are:

  1. Contention. Another job, e.g. a HSM backup, has hold of the file.

  2. Shareoptions. Normally SHROPTS is set to (3 3), but if the file is under LSERV control, they should be (1 3). Should you need to change it, then use IDCAMS ALTER and recycle L-Serv.

  3. Buffersize. If L-Serv is used for the file, the buffersize specified must match the CI size of the file concerned.