C1G0294E LISTING MEMBER COULD NOT BE FOUND

Document ID : KB000125110
Last Modified Date : 29/01/2019
Show Technical Document Details
Question:
We are moving  an element in a package and getting a Processor Return code of 12 with these errors:

C1G0000I DATA SET ENDV.TEST.LISTING
C1G0000I MEMBER DPRUNIFDP
C1G0294E LISTING MEMBER COULD NOT BE FOUND
C1X0010I STEP COPYLST PROGRAM CONLIST COMPLETED, RC=0012 

How can I resolve this? 
Answer:
The error message C1G0294E means: 

C1G0294E LISTING MEMBER COULD NOT BE FOUND 

Reason: 
The CONLIST processor program did not locate the specified listing member in the specified data set. The listing data set is identified by the C1LLIBI DD statement. This message is issued when the Copy or Print parameters are specified. 

Action: 
Verify that the listing member is present. You may have to regenerate the 
Element to recreate the listing. 

If you are moving the element you need to regenerate the element at the source location, then move it up the map.  If this does not resolve your problem, open a case with support and send them the full output from the generate and the move.