BPA0008E executing the Post Install CREATE job (ssid0001). How can this be resolved?

Document ID : KB000045159
Last Modified Date : 14/02/2018
Show Technical Document Details

Issue:

Execution of the Post Install Create job (ssid0001) results is this error: BPA0008E: SYNCPOINT xx WAS NOT FOUND.

 

This can occur when restarting the job.  It means the syncpoint the job is trying to start at is not found in the member being executed (ssidDDLU or ssidDDL). The BP Log record can be found by going into RC/Migrator, then Option 3 Execution Display. Put the BPID in from the Create job to see the row.  The STATUS column is how the Batch Processor job completed.

 

Resolution:

The normally sequence is to run the Compare (ssid0000), followed by the Create (ssid0001).  If the COMPARE is run again AFTER the CREATE job has partially completed,  contact technical support to determine the best way to complete the processing.

Running the Compare a 2nd time overwrites the ssidDDLU and ssidDDL members in hilvl.CDBASAMP.