Below the line storage shortages may lead to connection failures in the CA Common Services for z/OS CCI component.

Document ID : KB000008544
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

A CCI connection into z/OS failed to connect until another CCI connection had dropped.  Since there was very little below the line storage available to CCI, once the storage was freed, the connection was established.  

Environment:
z/os
Cause:

The bulk of the storage appears to be LE related possibly due to the Language Environment storage options in use.   

Resolution:

Use IBM’s RPTSTG option to review the LE storage options currently in effect and make the necessary option changes to achieve more efficient use of your "below the line" storage.

 

 

Additional Information: