Base Install of CA Database Management Solutions for DB2 for z/OS encounters: GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD Cxxxx00. HOLD REASON IDS WERE NOT RESOLVED.

Document ID : KB000030511
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

The native SMP/E (non-CSM) installation of the CA Database Management Solutions for DB2 for z/OS might encounter the following error during the APPLY process:
GIM30206E ** APPLY PROCESSING FAILED FOR SYSMOD Cxxxx00. HOLD REASON IDS WERE NOT RESOLVED.

This SMP/E Error condition can occur if the previous RECEIVE process for the Base product FMIDs included the comprehensive Error HOLDDATA file for the SMPHOLD DD allocation without also including the CA Database Management Solutions for DB2 for z/OS comprehensive maintenance file for the SMPPTFIN DD. 

Solution:

Although this type of failure can be bypassed by adding BYPASS(HOLDERROR) to the APPLY process, it is recommended that the Target platform (SMP/E Target data sets and CSI ) be deleted with the focus on starting over.  This time specify //SMPHOLD DD DUMMY on the RECEIVE job.  After successful execution of the RECEIVE, execute the APPLY and ACCEPT jobs for the Base product FMIDs.

Once the Base product FMIDs have been accepted then RECEIVE and APPLY the Error HOLDDATA and PTF maintenance file.