AWI PromptSet variables are not resolved on execution

Document ID : KB000084911
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
N/A

Within in a PromptSet in the Automic Web Interface (AWI) version 12, predefined Variables are not resolved in a Text field PromptSet.  If you use them as a default value, they remain as text after the object activation.  Also, if you use the Input Assistant of a PromptSet, you can pick a value but after clicking on the insert button nothing is inserted.

Investigation
 
Case 1
  1. Create a VARA
  2. Create a PromptSet
  3. Add the VARA to the PromptSet
 
Result of Case 1:  The VARA remains in a text format. 
 
Case2
  1. Create a PromptSet
  2. Include an existing Variable using {Variable} tab wizard assistance
Result of Case 2:  No variable can be selected.  
Environment:
OS: Windows
OS Version: N/A
Cause:
Cause type:
Defect
Root Cause: The Input Assistant of PromptSets causes the selected values not to be inserted into the corresponding input field.
Resolution:
Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automic Web Interface 12.1.0 - Available
Automic Web Interface 12.0. - Available
Additional Information:
Workaround :
Create a VARA and use in this way {VARA} in the PromptSet.