AWA NSK agent error: I/O ERROR: 201, $UC4OC.#KILLER

Document ID : KB000117417
Last Modified Date : 11/10/2018
Show Technical Document Details
Issue:
When attempting to start a newly installed NSK agent, an error occurs:

\AGENT.$UC4EX UC4.1.1 000053 $UC4EX Error 
4115 with bind_nw on socket (AWAITIO) 
\AGENT.$UC4EX UC4.1.1 000053 $UC4EX Error 
4115 with bind_nw on socket (AWAITIO) 
\AGENT.$X1RMG TANDEM.TACL.D46 000001 TACL DEVICE 
I/O ERROR: 201, $UC4OC.#KILLER 
Cause:
A review of the NSK agent's ucxjn61.ini file shows that the port= and cp= are configured incorrectly. 
Resolution:
1. Remove the IP address in the port= parameter. Enter only the port number the NSK agent is using. 
Example: 
format: port=portnumber 
port=3200 

2. Ensure the cp= parameter is pointing to the correct IP address or fully-qualified domain name of the server where the Automation Engine is installed. In this case, it was referencing the wrong IP address. 
Example: 
format: cp=AEservername:cp1port 
cp=10.111.9.222:2217