An object with a :WAIT between a :BEGINREAD and :ENDREAD block, gets stuck in "Generating" status

Document ID : KB000087528
Last Modified Date : 14/04/2018
Show Technical Document Details
Issue:
Error Message :
N/A

An object with a :WAIT between a :BEGINREAD and :ENDREAD block will cause the object to get stuck in status of “generating” and does not show the read-mask. 

If the option "generate at runtime" is set, the object will finish successfully.
Cause:
Cause type:
Defect
Root Cause: Block-read not working if :WAIT is used between :BEGINREAD and :ENDREAD commands.
Resolution:
This field was added on 30/03/2017. This article has not been updated yet. Refer to the "Description" or "Workaround" sections for solution information.

Fix Status: Released

Fix Version(s):
Component(s): AE Server and Initialdata

Automation Engine 11.2.3 - Available
Additional Information:
Workaround :
Check the option “generate at runtime” for the job.