After upgrading to a new release of IDMS I am getting error DFHSI1580D PLTPI program IDMSINTC has abended, code 4002

Document ID : KB000004014
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

After upgrading to a new release of IDMSĀ I am getting the following error in CICS:
DFHSI1580D PLTPI program IDMSINTC has abended, code 4002

Cause:

The 4002 error indicates IDMSINTC could not load a program.

Resolution:

The error can be caused by missing CSD entries in CICS or by a missing module in the DFHRPL concatenation. Check the following:

  • Ensure all CSD entries are defined, see CAGJSRC member CICSCSD for programs and transaction that need to be defined to CICS.

  • Ensure that both the CUSTOM.LOADLIB and CAGJLOAD libraries are defined to the CICS DFHRPL concatenation.