After upgrading to 10.2, the SiteMinder Single Sign-on host registration fails.

Document ID : KB000006997
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

When registering the Spectrum OneClick server as a trusted host on the OneClick Single Sign-On SiteMinder configuration page it fails with the following error message:

SPC-OCA-10300: Unable to register host with Policy Server. Verify parameters.

Environment:
Spectrum 10.2CA SiteMinder 12.52 SP01, 12.6
Cause:

The incorrect version of the smregHost executable and the SiteMinder libraries were shipped with 10.2

 

Resolution:

This issues is resolved with Spectrum_10.02.00.PTF_10.02.022 for Spectrum version 10.2.

Spectrum will now ship the correct version of the smregHost executable and the SiteMinder libraries to integrate successfully with SiteMinder.

Please contact CA Support to request this patch if you experience the above problem