After the installation of maintenance to my CA SYSVIEW PMO for DB2 for z/OS (IDB2) product, why isn't filtering on the Thread History panel working?

Document ID : KB000012464
Last Modified Date : 14/02/2018
Show Technical Document Details
Question:

I have applied maintenance to my Sysview Performance Monitor for DB2 for z/OS (IDB2), and now none of the filtering criteria I specify

on the Thread History panel is working.  What could be the cause?

Answer:

This specific condition was caused by a mismatch of code level derived from the library allocations in the INSIGHT CLIST being used.

The problem was corrected by ensuring the INSIGHT CLIST being executed had the correct allocations for the .CDBALOAD and .CDBAPNLO libraries, and that

all the library allocations taking place within this clist reflected the newly applied maintenance level of code.  

Once these allocations were correctly referenced, filtering on the Thread History panel worked.