After installing CA SymDump Batch or CA Optimizer/II r 8.5 and implementing the LE exit no dump is captured by either product when executing the demo program. Instead a U4039 abend is generated.

Document ID : KB000051454
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

Chapter six of the installation guide for CA SymDump Batch and CA Optimizer/II 8.5 outline the language environment (LE) installation considerations. After the LE configuration for either product has been completed you execute the DEMO program shipped to verify the installation. When executing the DEMO program which produces an abend by design neither product captures the abend and LE generates a user U4039 abend.

Solution:

After the LE configuration for either product has been completed you execute the DEMO program shipped to verify the installation you receive a U4039 abend (Below) and no dump is captured by CA SymDump Batch and CA Optimizer/II.

 
IEA995I SYMPTOM DUMP OUTPUT  676
  USER COMPLETION CODE=4039 REASON CODE=00000000
 TIME=12.59.49  SEQ=00539  CPU=0000  ASID=003A
 PSW AT TIME OF ERROR  078D1000   868D79FE  ILC 2  INTC 0D
   NO ACTIVE MODULE FOUND
   NAME=UNKNOWN
   DATA AT PSW  068D79F8 - 00181610  0A0D58D0  D00498EC
   AR/GR 0: 8EB7AEDE/84000000   1: 00000000/84000FC7
         2: 00000000/0008BA78   3: 00000000/00060007
         4: 00000000/068CC0D8   5: 00000000/0008B5DC
         6: 00000000/00000000   7: 00000000/0F35E2A8
         8: 00000000/0008BA78   9: 00000000/0008D156
         A: 00000000/0008B5DC   B: 00000000/068D7928
         C: 00000000/00077B58   D: 00000000/0008E278
         E: 00000000/868CB1BC   F: 00000002/00000000
 END OF SYMPTOM DUMP
 

This is known problem caused by LE option TERMTHDACT(UADUMP).

The CA SymDump Batch and CA Optimizer/II installation guide states that no dump will be captured if your LE configuration uses TERMTHDACT(UADUMP).

Note: The LE option TERMTHDACT(UADUMP) generates a U4039 abend when an unhandled condition occurs of severity 2 or greater.
CA SymDump Batch or CA Optimizer/II will not report on this abend.

As a test you may what to set TERMTHDACT(TRACE,,96).