Admin console for probe SNMPCollector not able to open, Error Code: PPM 012

Document ID : KB000006506
Last Modified Date : 14/02/2018
Show Technical Document Details
Issue:

Problem:

Customer is getting the below error when clicking of SNMPC admin console "configure".

Unable to read configuration
Configuration was unable to be retrieved.

Message: Remote Request Error: Remote /uim_prod/xap-pvapuim03/xap-pvapuim003/snmpcollecotr probe processing of operation get_ctd_configuration failed.

Resolution: Please check both the PPM and remote probe log file for additional details.
Error Code: PPM 012

Click Retry to attempt to save your configuration again.
Click Close to close this Window

 

Environment:
Environment:snmp collector probe version:- 3.31UIM version:- 8.47 PPM version:-3.4
Cause:

Cause:

By default the snmpcollector database, (a file called snmpcollector.mv.db), runs in embedded mode and allows only one connection.  If that connection to snmpcollector fails, it does not allow another.

Error message in log:

/opt/nimsoft/probes/network/snmpcollector/SnmpCollector.mv.db failed; file length -1 read length 32 at 184866602

Resolution:

Resolution:

-- open the probe snmpcollector Raw Configuration.  Under setup add the key: DB_SERVER_MODE = true
-- Deactivate and Activate the SNMPcollector probe