Issue:
Integrated VNA 3.5.1 with Spectrum 10.2.3. Integration is successful, and Spectrum started displaying alerts but mapped fault with wrong interface. Alarms details include correct interface but alarm title shown on wrong interface. 
Cause:
Root cause was determined to be within Spectrum. Changes are in place to be available in Spectrum 10.3
Resolution:
Now VNA ACI alerts will be mapped to the proper interface. This fix will be included in Spectrum 10.3.