Abend S0C4 in DBINRPR at or near x'4E12' when executing program DDCFBLD to do HSD RESET.

Document ID : KB000017389
Last Modified Date : 14/02/2018
Show Technical Document Details

Description:

CA Datacom batch utility DDCFBLD is failing with an S0C4 abend in DBINRPR at x'4E12' (or x'4AFE') when attempting to do an HSD RESET.

Solution:

That symptom has occurred when the DDURT002 load module had been link edited as reentrant/reusable (RENT/REU) and is in an APF authorized STEPLIB library.

A quick way to check is to browse the load library and check the attributes of the DDURT002 load module.

The attributes RN RU indicate that it was link edited as reentranct (RN) and reusable (RU).


          Name     Prompt        Alias-of    ---- Attributes ----      SSI
_________ DDURT002                             RN RU

If RN/RU, DDURT002 must be re-link edited.